NOTICE  
This appliance is intended for professional use only and is to be operated by qualified personnel only. A  
Frymaster/DEAN Factory Authorized Service Center (FASC) or other qualified professional should  
perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified  
personnel may void the manufacturer’s warranty.  
NOTICE  
This equipment must be installed in accordance with the appropriate national and local codes of the  
country and/or region in which the appliance is installed.  
NOTICE TO U.S. CUSTOMERS  
This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and  
Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food  
and Drug Administration.  
DANGER  
Improper installation, adjustment, maintenance or service, and unauthorized alterations or modifications  
can cause property damage, injury, or death. Read the installation, operating, and service instructions  
thoroughly before installing or servicing this equipment. Only qualified service personnel may convert  
this appliance to use a gas other than that for which it was originally configured.  
DANGER  
Adequate means must be provided to limit the movement of this appliance without depending upon the  
gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. If a  
flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is  
in use.  
DANGER  
The front ledge of the fryer is not a step! Do not stand on the fryer. Serious injury can result from slips  
or contact with the hot oil.  
DANGER  
Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other  
appliance.  
DANGER  
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak must be  
posted in a prominent location. This information can be obtained from the local gas company or gas  
supplier.  
NOTICE  
IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT  
OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM  
FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED  
IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER,  
FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR  
EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN  
PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN  
UNAUTHORIZED SERVICE CENTER.  
NOTICE  
The Commonwealth of Massachusetts requires any and all gas products to be installed by a  
licensed plumber or pipe fitter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUPER RUNNER SERIES GAS FRYERS  
CHAPTER 1: INSTALLATION INSTRUCTIONS  
1.1 Safety Information  
Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual you will  
find notations enclosed in double-bordered boxes with the symbol The information contained in the box concerns  
.
actions or conditions that may cause or result in injury to personnel or damage to your system, and/or cause your system  
to malfunction.  
1.2 General Installation Instructions  
DANGER  
Building codes prohibit a fryer with its open frypot of hot oil being installed beside an open flame of any  
type, including those of broilers and ranges.  
DANGER  
This appliance must be installed with sufficient ventilation to prevent the occurrence of unacceptable  
concentrations of substances harmful to the health of personnel in the room where it is installed.  
DANGER  
No structural material on the fryer should be altered or removed to accommodate placement of the fryer  
under a hood.  
DANGER  
Single fryers must be restrained to prevent tipping when installed in order to avoid the splashing of hot  
liquid. The means of restraint may be the manner of installation, such as connection to battery of  
appliances or installing the fryer in an alcove, or by separate means, such as straps or chains.  
DANGER  
Do not attach an apron drainboard to a single unit. The appliance may become unstable, tip over, and  
cause injury. The appliance area must be free and clear of combustible material at all times.  
NOTICE  
This appliance is only for professional use and shall be used by qualified personnel only.  
CLEARANCE AND VENTILATION  
This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to  
combustible construction. No clearance is required when installed adjacent to non-combustible construction.  
minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer.  
A
The fryer flue opening must not be placed close to the intake of an exhaust fan, and the fryer must never have its flue  
extended in a "chimney" fashion. An extended flue will change the combustion characteristics of the fryer. To provide  
the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear  
must be kept clear and unobstructed.  
The fryer must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be  
maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at  
an angle of 45°. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96  
states, "A minimum distance of 18-inches (450-mm) should be maintained between the flue outlet and the lower edge of  
the grease filter". Frymaster recommends that the minimum distance be 24-inches (600-mm) from the flue outlet to the  
bottom edge of the filter.  
INSTALLATION  
NOTE: Unless special ordered, this fryer is designed for operation at altitudes of 2000 feet (610 meters) and below.  
The unit must be modified for operation above 2000 feet (610 meters).  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUPER RUNNER SERIES GAS FRYERS  
CHAPTER 1: INSTALLATION INSTRUCTIONS  
For units equipped with legs: Lift the unit and move it into its final position. Do not drag or push the fryer into position.  
Doing so may damage the legs. Level the unit front to back and side to side. If the fryer is not level, the unit will not  
function efficiently. Super Runner Series gas fryers cannot be curb mounted and must be equipped with either legs or  
casters provided.  
A. Adjust leg height with an adjustable or 1-1/16-inch (27-mm) open-end wrench by turning the hexagon-shaped foot  
on the bottom of the leg. NOTE: The foot is for minor leg height adjustment only. Do not adjust outward more  
than ¾-inch (19-mm).  
B. When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the  
foot to the required height.  
For units equipped with casters: Roll the unit into its final position and lock the front casters.  
1.3 Pre-Connection Preparation  
WARNING  
If the incoming gas pressure is in excess of ½" PSI (3.45 kPa/35 mbar), a step-down regulator will be  
required.  
CE UNITS ONLY:  
Dean Super Runner gas fryers have obtained CE markings for countries and gas categories shown below:  
Countries  
Supply Pressures and Gas (mbar)  
Appliance Categories  
G20  
G31  
20/25  
37  
BE  
Belgium  
IIE(R)B3P  
G20  
G31  
G20  
G20  
G31  
G20/G25  
G31  
G20  
G31  
G20  
G31  
G20  
G31  
20  
50  
20  
20  
37 and 50  
20/25  
37 and 50  
20  
I2E  
I3P  
I2H  
DE  
DK  
ES  
Germany  
Denmark  
Spain  
II2H3P  
II2ESI3P  
II2H3P  
II2H3P  
FR  
GB  
GR  
France  
Great Britain  
Greece  
37  
20  
37 and 50  
20  
37  
IR  
IT  
Ireland  
II2H3P  
I2H  
Italy  
G20  
20  
G20/G25  
G31  
20/25  
50  
LU  
Luxembourg  
II2E3P  
G25  
G31  
G20  
G31  
25  
50  
20  
37  
NL  
PT  
The Netherlands  
Portugal  
II2L3P  
II2H3P  
NON-CE UNITS ONLY:  
NATIONAL CODE REQUIREMENTS:  
This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code  
Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug  
Administration.  
This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect  